Pipe Size Reference Chart: Nominal and Outer Diameters

Pipe nominal diameter and actual outer diameter often do not match in piping standards.


For that reason, we recommend checking the actual outer diameter rather than the nominal diameter. In this article, we’ve compiled the recommended compatible sizes for our products based on the nominal diameters and outer diameters of PVC pipe, steel pipe, and copper pipe.

What you’ll learn in this article

  • Why nominal diameter and actual outer diameter differ
  • Nominal diameter, outer diameter, and recommended compatible sizes by pipe type
  • Points to note when checking sizes

The difference between "nominal diameter" and "outer diameter"

塩ビ管VP、鋼管GP、銅管CUの呼び径規格比較

Nominal diameter is basically a standardized piping term based on "inner diameter", so, as shown in the table below, the outer diameter of the pipe often differs.


Pipe type Nominal diameter Inner diameter Outer diameter
PVC pipe VP20 20mm 26mm
Steel pipe 20A around 21.6mm 27.2mm

 

Therefore, we recommend choosing the appropriate compatible size based on the actual outer diameter rather than the nominal diameter. Below, along with compatibility tables for nominal diameter and outer diameter by pipe type, we summarize the recommended compatible sizes for our products.

PVC pipe (VP) nominal diameter / outer diameter compatibility table

Nominal diameter Outer diameter Compatible products
Saddle Clamp
VP13 18mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

VP16 22mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

VP20 26mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

VP25 32mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

VP30 38mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

VP40 48mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

VP50 60mm

Standard type

Standard type

Anti-vibration type

VP65 76mm

-

Standard type

Anti-vibration type

VP75 89mm

-

Standard type

VP100 114mm

-

Standard type

Steel pipe (GP) nominal diameter / outer diameter compatibility table

Nominal diameter Outer diameter Compatible products
Saddle Clamp
10A 17.3mm

Standard type

Anti-vibration type

Anti-vibration type

15A 21.7mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

20A 27.2mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

25A 34.0mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

32A 42.7mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

40A 48.6mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

50A 60.5mm

Standard type

Standard type

Anti-vibration type

65A 76.3mm

-

Standard type

Anti-vibration type

80A 89.1mm

-

Standard type

100A 114.3mm

-

Standard type


* Some sizes are approximate, but installation is still possible without any issues.

Copper pipe (CU) nominal diameter / outer diameter compatibility table

Nominal diameter Outer diameter Compatible products
Saddle Clamp
CU13 15.88mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

CU16 19.05mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

CU20 22.23mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

CU25 28.58mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

CU32 34.92mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

CU40 41.28mm

Standard type

Anti-vibration type

Standard type

Anti-vibration type

CU50 53.98mm

Anti-vibration type

Standard type

Anti-vibration type

CU65 66.68mm

-

Standard type

CU80 79.38mm

-

Standard type


* Please note that nominal diameter and outer diameter may differ depending on the application, such as copper pipe for building plumbing or copper refrigerant pipe (including insulation).


* Some sizes are approximate, but installation is still possible without any issues.

Notes when checking pipe size

In some cases, actual measurement is necessary

Depending on the pipe type and usage conditions, the actual dimensions may vary slightly. If you are unsure, we recommend measuring directly with calipers or a measuring tape. For the correct measuring method, please see How to Measure Pipe Outer Diameter | How to Check Size with Calipers and a Measuring Tape.